beautypg.com

Single preset models, Dual preset models, 3 preset batch models – Red Lion C48C User Manual

Page 3: Prescaler output models, Front panel features

background image

3

8. OUTPUTS: (Output type and quantity, model dependent) Cont’d

Relay: Form A contact, Rating = 5 A @ 250 VAC, 30 VDC (resistive load),

1/10 HP @ 120 VAC (inductive load)
Relay Life Expectancy: 100,000 cycles min. at max. load rating

Programmable Timed Output: User selectable output time resolution.

0.01 Second Resolution: 0.01 to 99.99 sec, ± 0.01% +20 msec max.

(Prescalers less than 2)

0.1 Second Resolution: 0.1 to 999.9 sec, ± 0.01% + 100 msec (Prescalers

less than 2)

Note: For Prescaler values above 2, the timed delay output is affected by

the count speed (rate).

9. RS485 SERIAL COMMUNICATIONS (Optional): Up to 32 units can be

connected.
Baud Rate: Programmable from 1200 to 9600 baud
Address: Programmable from 0 to 99
Data Format: 10 Bit Frame, 1 start bit, 7 or 8 data bits, 1 or No Parity bit,

and 1 stop bit

Parity: Programmable for Odd (7 data bits), Even (7 data bits), or None (8

data bits)

10. CERTIFICATIONS AND COMPLIANCES:

UL Recognized Component, File #E137808

Recognized to U.S. and Canadian requirements under the Component
Recognition Program of Underwriters Laboratories, Inc.

ELECTROMAGNETIC COMPATIBILITY

Notes:
AC VERSIONS
1. A power line filter, RLC#LFIL0000 or equivalent, was installed when the

unit was DC powered.

DC VERSIONS

To insure compliance with the EMC standards listed above, do not connect
any wires from the terminal(s) labeled “COMM.” to the “DC-” supply
terminal (12), when powering the unit from a DC supply.

Refer to EMC Installation Guidelines section of the manual for additional

information.

11. ENVIRONMENTAL CONDITIONS:

Operating Temperature: 0°C to 50°C
Storage Temperature: -40°C to 70°C
Operating and Storage Humidity: 85% max. relative humidity
(non-condensing) from 0°C to 50°C.
Altitude: Up to 2000 meters

12. ELECTRICAL CONNECTIONS: Wire clamping screw terminals.
13. CONSTRUCTION: Black plastic case with collar style panel latch. The

panel latch can be installed for horizontal or vertical stacking. Black plastic
textured bezel with clear display viewing window. Unit assembly with circuit
boards can be removed from the case without removing the case from the
panel or disconnecting the wiring. Front panel meets NEMA 4X/IP65
requirements for indoor use, when properly installed. Installation Category
II, Pollution Degree 2.

14. WEIGHT: 6.0 oz (170 g)

SINGLE PRESET MODELS

The C48CS has a solid-state output that operates in parallel with a relay

output. The solid-state output is available as an NPN or PNP open collector
transistor.

DUAL PRESET MODELS

The C48CD has two outputs that are activated from presets 1 and 2

respectively. These outputs can be relay outputs, or solid-state outputs. The
solid-state outputs are available as NPN or PNP open-collector transistors. Units
with solid-state outputs can be ordered with an optional prescaler output
(C48CP).

3 PRESET BATCH MODELS

The C48CB has a secondary counter that can be used for batch counting, or

to keep a total count. This second counter can be programmed to operate in one
of eight operating modes. Outputs 1 and 2 are assigned to the primary process
counter (C1). Output 3 is assigned to the secondary Batch/Total counter (C2).
The three preset batch unit can be ordered with solid-state or relay outputs.
Units with solid-state outputs have a User Input 2 terminal available. The relay
model has a relay output for Output 2 and Output 3 (Batch/Total). Output 1 is
available only as solid-state.

PRESCALER OUTPUT MODELS

The C48CP is a dual preset counter with solid-state outputs. These models

have an additional output configured as a prescaler output. Each time the least
significant digit of the display increments, the Prescaler output provides a pulse.
The width of this pulse is variable in that the output will turn off after a
programmed number of count input pulses has occurred (1-9). The Prescaler
output can also be programmed to activate when the 10’s digit of the display
increments, rather than the least significant digit.
Note: Prescaler Output models are limited to two programmable count modes

and prescaler values of 1.00000 or less. See Count Input Modes for available
modes.

FRONT PANEL FEATURES

The C48 Counters feature a dual line display. In the normal operating mode

(main display), the count or batch/total value is shown on the top line and
presets, prescaler, or output time values are shown on the bottom line. The
bottom line values can be programmed to be viewable only, viewable and
changeable, or locked (not viewable) from the main display.

In the operating mode, the presets, prescaler, and output time values are

accessible providing that these values are not programmed for ‘L’ocked. Values
that are accessible (changeable) can be changed immediately when viewed in
the secondary display.

FRONT PANEL KEYPAD

!

- Performs user Programmed Function

- Cycles through secondary displays.

"

- Enters Protected Value Menu or Programming Mode

when pushed and held for 2 seconds.

- Scrolls through programming parameters.
- Enters Data Values.

- Selects next available mode in programming mode.

#

- Increments digit in Digit Entry mode.
- Increments value in Auto Scrolling entry mode.

- Selects Digit to right when in Digit Entry mode.

$

- Decrements value in Auto Scrolling entry mode.

Enclosure class A

EN 55011

RF interference

Emissions to EN 50081-2

Level 3; 10 V/m

ENV 50204

Simulation of cordless telephone

150 KHz - 80 MHz

Level 3; 10 V/rms

EN 61000-4-6

RF conducted interference

Level 3; 2 Kv power

Level 4; 2 Kv I/O

EN 61000-4-4

Fast transients (burst)

80 MHz - 1 GHz

Level 3; 10 V/m

EN 61000-4-3

Electromagnetic RF fields

Level 3; 8 Kv air

Level 2; 4 Kv contact

EN 61000-4-2

Electrostatic discharge

200 Hz, 50% duty cycle

Immunity to EN 50082-2

900 MHz ± 5 MHz