Modifier

Description

ux

Name of the measurement unit using x number of characters. For
example, u3 shows the name of the measurement unit with three
characters.

addr

Transmitter address.

sn

Transmitter serial number.

time

Time since transmitter was started or reset.

cs4

Modulus-65536 checksum of message sent so far, ASCII encoded
hexadecimal notation.

csx

NMEA xor-checksum of message sent so far, ASCII encoded
hexadecimal notation

You can also use the hash character # instead of the backslash
character \.

Serial Line Communication

Syntax

Description

open [aaa]

Open a connection to a device at the
specified address. Required when device is
in poll mode. Address range 0 ... 255.

Example:

open 5
HMD112

5 line opened for operator commands

Table 18 Open Command

Syntax

Description

close

Close the connection that was opened with
the open command.

Example:

close
line closed

Table 19 Close Command

Syntax

Description

addr

Show current device address and prompt for
a new address.

addr [aaa]

Set new device address.

aaa

= 0 ... 255.

Example (shows 0 as current address, enter 5 as the new address):

addr
Address

:

0

?

5

Table 20 Addr Command