beautypg.com

DAVIS Vantage Pro2/Pro2 Plus: Temperature/Humidity Station User Manual

Page 11

background image

11

S p e c i f i c a t i o n s

General

Operating Temperature . . . . . . . . . . . . . . . . . . . . . . -40° to +150° F (-40° to +65° C)
Non-operating Temperature . . . . . . . . . . . . . . . . . . . -50° to +158° F (-45° to +70° C)
Current Draw, Sensors & Transmitter only . . . . . . . . 0.14 mA (average), 30 mA

(peak) at 3 VDC

Battery: Sensors & Transmitter. . . . . . . . . . . . . . . . . CR-123 3-Volt Lithium cell
Battery Life . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 months
Sensor Type

Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . Thermistor

Relative Humidity . . . . . . . . . . . . . . . . . . . . . . . Film capacitor element

Housing Material . . . . . . . . . . . . . . . . . . . . . . . . . . . UV-resistant PVC plastic
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.25" wide x 7.25" long x 7.75"

high (210 mm x 184 mm x 197

mm)

Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.5 lbs. (.1.6 kg)

Wireless Communications

Transmit/Receive Frequency

. . . . . . . . . . . . . . . . . US Models: 902-928 MHz

FHSS, Overseas Models: 868.0
- 868.6 MHz FHSS.

ID Codes Available

. . . . . . . . . . . . . . . . . . . . . . . . . 8

Output Power

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 902-928 MHz FHSS:

FCC-certified low power, less
than 8 mW, no license required
868.0 - 868.6 MHz FHSS.
CE-certified, less than 8 mW, no
license required

Range

Line of Sight . . . . . . . . . . . . . . . . . . . . . . . . . . . up to 1000 feet (300 m)
Through Walls . . . . . . . . . . . . . . . . . . . . . . . . . 200 to 400 feet (75 to 150 m)

Sensor Output (as used by Davis Instruments weather station consoles.)

Temperature (Air)

Resolution and Units. . . . . . . . . . . . . . . . . . . . . 1°F or 1°C (user-selectable)

Range. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -40° to +150° F (-40° to +65° C)

Sensor Accuracy. . . . . . . . . . . . . . . . . . . . . . . . ±1°F (±0.5°C) under 110°F

(43°C), ±2°F (±1°C) over 110°F

(43°C)

(see chart)

Radiation Induced Error . . . . . . . . . . . . . . . . . . +2°F (1°C) at solar noon

(insolation = 1040 W/m2, avg.

wind speed 2 mph (1 m/s))

Update Interval . . . . . . . . . . . . . . . . . . . . . . . . . 10 seconds

Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Instant Reading (user

adjustable)

Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . High and Low Thresholds from

Instant Reading

Relative Humidity

Range. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 to 100% RH

Accuracy. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±3% (0 to 90% RH), ±4% (90 to

100% RH)

Drift . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . up to ±2% per year

Update Interval . . . . . . . . . . . . . . . . . . . . . . . . . every 50 seconds

Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Instant (user adjustable)

Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . High and Low Threshold from

Instant Reading