Logger type, Time out period, Station configuration – DAVIS WeatherLink for Alarm Output Add. User Manual
Page 3
3
Logger Type
The software indicates the logger type and firmware revision level of the
streaming data logger in the logger type box.
Time Out Period
The Alarm Output data logger will always hold an attached device in the
appropriate state (On or Off) as dictated by the alarm settings. However,
the Alarm Output data logger utilizes a time-out period for ceasing check-
ing the alarm conditions whenever software attempts to communicate to
the logger. The default and minimum setting is 5 seconds. Once the time
out period ends, the data logger will again check the alarm conditions to
determine whether to leave an output open or closed. You may adjust this
value if you want the alarm checking functions to resume later after com-
municating to the logger using WeatherLink or the Streaming Data Utility.
Press OK to configure this setting in the dialog box. Press Cancel to exit
the dialog box and preserve the original settings.
Note:
Once communications with WeatherLink software are initiated and successful, the streaming data
logger will be unable to communicate with the Streaming Data Utility until the Time Out Period
expires. If you need to communicate to the logger with both the Streaming Data Utility and Weath-
erLink, you should communicate using the Streaming Data Utility first.
Station Configuration
Before setting alarms, use this function to indicate what sensors you have
with your Vantage Pro2 or Vantage Pro system. The Configuration Utility
uses your choices to determine what parameters to show in the list. (You