beautypg.com

HP Integrity Superdome 2 Server User Manual

Page 99

background image

Diagnostic information is gathered by polling a device microcontroller (resulting in a degraded
status if a failure has occurred) or is sent by the device microcontroller, without being polled, to
report a failure.

Active Onboard Administrator Status and Information tab

Table 8 Status information

Description

Item

The overall status of the enclosure. Possible values are Unknown, OK, Degraded, and Failed.

Status

Active or Standby.

Role

The physical bay number where the Onboard Administrator is installed.

Bay Number

The temperature of the enclosure in degrees Fahrenheit.

Temperature

The temperature at which the enclosure reports a status of caution.

Caution Threshold

The temperature at which the enclosure reports a critical status and powers off.

Critical Threshold

Hardware information

Description

Item

The common descriptive name of the Onboard Administrator.

Device Name

The name of the company that manufactured the Onboard Administrator.

Manufacturer

The version of the complex firmware image in the Onboard Administrator.

Complex Firmware
Version

The version of the enclosure hardware.

Hardware Version

The part number to use when ordering an additional or replacement Onboard Administrator.

Part Number

Onboard Administrator Module

99