beautypg.com

Device power sequence interconnect bays tab, Date and time screen, Static date and time settings – HP Integrity Superdome 2 Server User Manual

Page 87

background image

Description

Column

Enables power sequencing, disables power sequencing,
or does not allow powering on of the device if No Poweron
is selected.

Enabled

The amount of delay, in seconds, before the device powers
on.

Delay

Device Power Sequence Interconnect Bays tab

Description

Column

Bay number of the device

Bay

The type of device in the bay or Absent if no device is
installed in the bay

Device

Enables power sequencing, disables power sequencing,
or does not allow powering on of the device if No Poweron
is selected.

Enabled

The amount of delay, in seconds, before the device powers
on. Possible delay values are 1 to 3600.

Delay

Click the Apply button to save the settings.

Date and Time screen

NOTE:

The RTC in an nPartition is synced to OA time when the nPartition is rebooted. If you

change the time on the OA, it may affect the RTC on the nPartition.

Static date and time settings

The date and time are static and not updated in real-time. The date and time can only be set when
NTP is disabled.

Description

Possible value

Box

The date assigned to the enclosure

yyyy-mm-dd

Date

mm is an integer from 1 to 12

dd is an integer from 1 to 31

The time assigned to the enclosure

hh:mm:ss (24-hour time, ss is optional)

Time

hh is an integer from 0 to 23

mm is an integer from 0 to 59

ss is an integer from 0 to 59

The time zone assigned to the enclosure

Time zone settings

Time Zone

“Africa time zone settings” (page 190)
“Americas time zone settings” (page 190)
“Asia time zone settings” (page 192)
“Universal time zone settings” (page 192)
“Oceanic time zone settings” (page 193)
“Europe time zone settings” (page 193)
“Polar time zone settings” (page 194)

Enclosure settings

87