Port Mapping Information

Information regarding port mapping for all devices in the device bay is available by clicking the
Port Mapping Information link.

Status information

Description

Item

The overall status of the blade. Possible values are Unknown, OK, Degraded, Failed,
or Other with an informational icon. The informational icon with an Other status displays

Status

until the server blade is configured for Virtual Connect Manager. See the Diagnostic
Information table for more information.

The power state of the blade. Possible values are On or Off.

Powered

The amount of power allocated to the blade in watts.

Power Allocated

The temperature of the blade in degrees Celsius and Fahrenheit.

Ambient Temperature

NOTE:

Not applicable for HP Integrity Superdome 2 server blades.

The temperature thresholds at which the server blade displays a degraded status because
of a thermal condition.

Ambient Caution Threshold

NOTE:

Not applicable for HP Integrity Superdome 2 server blades.

The temperature thresholds at which the server blade powers off because of a degraded
thermal condition.

Ambient Critical Threshold

NOTE:

Not applicable for HP Integrity Superdome 2 server blades.

The storage blade the server blade is partnered with. This information does not display
if there is no partner device.

Partner Device

NOTE:

Not applicable for HP Integrity Superdome 2 server blades.

Diagnostic Information

Diagnostic information is gathered by polling a device microcontroller (resulting in a degraded
status if a failure has occurred) or is sent by the device microcontroller, without being polled to
report a failure.

Description

Item

Contains information on model name, part number, serial number, and other information
used to identify the device. This data is also called FRU data. Device identification data
error displays if the data is not present or not readable by the Onboard Administrator.

Device Identification Data

Status of the iLO. Possible values are OK or Error.

Management Processor

Temperature is above the warning threshold. Possible values are OK or Temperature
Warning.

Temperature

Temperature is above the danger threshold. Possible values are OK or Critical
temperature threshold reached.

Overheat Check

Device bay configuration is incorrect. If a storage blade is partnered with a full height
server blade, and the server blade does not have the correct mezzanine card, an invalid

I/O Configuration

I/O configuration will result. Possible values are OK or I/O mismatch detected. See
the EBIPA section for more information.

There is insufficient power to adequately power this server blade. Possible values are
OK or Insufficient enclosure power.

Power Allocation Request

There are an insufficient number of fans to properly cool this server blade or the fan
configuration is incorrect. Possible values are OK or Insufficient fans for enclosure
cooling.

Cooling