IOX Power Subsystem screen

The Power Subsystem screen shows the overall status of the IOX enclosure power subsystem and
information about each power supply in the IOX enclosure.

Power supplies available for use in IOX enclosures

All power supplies in one IOX enclosure must have the same part number. The Onboard
Administrator identifies which power supplies must be replaced by displaying a caution icon.

Power Supply summary

The Power Subsystem screen provides status on the power subsystem, on each individual power
supply, and fault conditions.

Description

Item

The overall power status of the IOX enclosure. Possible values are Unknown, OK,
Degraded, or Critical Error.

Power Subsystem Status

Indicates the redundancy status of the power subsystem. Possible values are Redundant,
Not Redundant, or Redundancy Lost.

Redundancy State

This screen provides status on the power subsystem and on each individual power supply.

Power Supply status

Description

Item

The bay in the IOX enclosure of the corresponding power supply. This box displays only
populated bays. Empty bays do not appear in this table.

Bay

The power supply model name.

Model

The overall status of the power supply. Possible values are Unknown, OK, Degraded,
and Critical Error.

Status

The input status of the power supply. Possible values are Unknown, OK, Degraded, and
Critical Error.

Input Status

160 HP Integrity Superdome 2 IOX Enclosures