Description

Insight Display
name

Mode

to full performance. This mode is not supported for low voltage on the
Superdome 2 enclosure.

An optional setting to limit power. Whenever you attempt to power on
a device, the total power demands of the new device and of the devices

Power Limit

Power Limit

already on are compared against this Static Power Limit. If the total
power demands exceed the limit, the new device is prevented from
powering on.

Dynamic Power-The default setting is Enabled. The following selections are valid:

Enabled— Some power supplies can be automatically placed on standby to increase overall
enclosure power subsystem efficiency.

Disabled— All power supplies share the load. The power subsystem efficiency varies based
on load.

Dynamic Power is not supported for low voltage on the Superdome 2 enclosure.

Enclosure Power Allocation screen

To set the power management options in Onboard Administrator, go to the menu on the left and
select the enclosure to be managed, and then click Power and Thermal. The Enclosure Power
Allocation page appears below. Click Enclosure Power Allocation to display the following
information:

Description

Item

The overall power status of the enclosure. Possible values are unknown, OK, Degraded,
and Failed.

Subsystem Status

The amount of power consumed by the devices in the enclosure in watts.

Power Allocated