beautypg.com

Interconnect bay status tab status information, Diagnostic information – HP Integrity Superdome 2 Server User Manual

Page 120

background image

Interconnect Bay Status tab

Status information

Description

Item

The overall status of the interconnect device. Possible values are Unknown, OK, Degraded,
and Failed.

Status

The thermal status of the interconnect device. Possible values are Unknown, OK, Degraded,
and Failed.

Thermal Status

The power state of the interconnect device. Possible values are On or Off.

Powered

Diagnostic Information

Description

Row

Contains information on model name, part number, serial
number, and other information used to identify the device.

Device Identification Data

This data is also called FRU data. Device identification
data error displays if the data is not present or not readable
by the Onboard Administrator.

Management processor is not responding. Possible values
are OK or Error.

Management Processor

Temperature is above the warning threshold. Possible
values are OK or Temperature Warning.

Temperature

Temperature is above the danger threshold. Possible values
are OK or Critical temperature threshold reached.

Overheat Check

Device has failed; status was not requested by the Onboard
Administrator. Possible values are OK or Error.

Device Operational

Device has failed; status was requested by the Onboard
Administrator. Possible values are OK or Error.

Device Degraded