background image

Description

Item

The server blade has been placed in the wrong slot in the enclosure according to the
current fan configuration. Possible values are OK or Incorrect location for proper device
cooling.

Device Location

Device has failed; status was not requested by the Onboard Administrator. Possible
values are OK or Error.

Device Operational

Device has failed; status was requested by the Onboard Administrator. Possible values
are OK or Error.

Device Degraded

Device has an error. Possible values are OK or an Informational message.

NOTE:

Not applicable for c-Class server blades.

Device Informational

The now configured partition firmware version does not match the now configured
complex firmware bundle version. Possible values are OK or Error.

NOTE:

Not applicable for c-Class server blades.

Firmware Mismatch

The now configured device firmware version does not match the now configured complex
firmware bundle version. Possible values are OK or Error.

NOTE:

Not applicable for c-Class server blades.

Device Mismatch

The device has a duplicate IP address. Possible values are OK or Error.

NOTE:

Not applicable for c-Class server blades.

Duplicate IP Address

Indicates if the device has been indicted by the Superdome 2 Analysis Engine. Possible
values are OK or Error with an informational message.

NOTE:

Not applicable for c-Class server blades.

Device Indictment

Possible values are OK or Inappropriate device in adjacent bay. This information does
not display if the server blade is not partnered with a storage blade.

Partner Device Link

NOTE:

Not applicable for HP Integrity Superdome 2 server blades.

Possible values are Configured for Virtual Connect or Not configured for Virtual Connect.
When the server blade is Not configured for Virtual Connect an informational icon with

Virtual Connect Configured

an Other status displays. Go to the Virtual Connect Manager to configure the server
blade profile.

NOTE:

Not applicable for HP Integrity Superdome 2 server blades.

CPU Status

Description

Item

The resource path for the processor socket.

Resource Path

The overall status of the processor. Possible values are Unknown, OK, Degraded, or
Failed.

Status

The status of the FRU data for the processor. Possible values are Unknown, OK,
Degraded or Failed.

FRU Read Status

The indictment status of the processor. Possible values are OK or Error with an
informational message.

Indictment Status

DIMM Status: CPU Socket 0 or 1

Description

Item

The resource path for the DIMM socket.

Resource Path

The overall status of the DIMM. Possible values are Unknown, OK, Degraded, or Failed.

Status

Device bays