HP Integrity Superdome 2 Server User Manual
Page 84

NOTE:
The Alert Sender Domain might not be required. The information in this box depends on
the mail server setup.
Description
Possible value
Box
This box is a valid email address for
the administrator or other designated
individual receiving the AlertMail
E-mail address
The domain in which the Onboard
Administrator resides
A character string including all
alphanumeric characters and the dash
(-)
Alert Sender Domain
An IP address for the SMTP server
###.###.###.### where ### ranges
from 0 to 255
SMTP Server
To enable the AlertMail feature:
1.
Select the Enable AlertMail check box to enable the AlertMail feature.
2.
Enter values for the email address, alert sender domain, and SMTP server.
3.
Click the Apply button to save the settings.
AlertMail, if enabled, sends alerts by email for the following events:
•
Enclosure status change
•
Enclosure information change
•
Fan status change
•
Fan inserted
•
Fan removed
•
Power supply status
•
Power supply inserted
•
Power supply removed
•
Power supply overload
•
Blade inserted
•
Blade removed
•
Blade status
•
Blade thermal condition
•
Blade fault
•
Blade information change
•
Tray status change
•
Tray reset
•
Switch connect
•
Switch disconnect
All e-mails have the following header:
From: Enclosure ENCLOSURE-NAME
Date: Date in standard format
Subject: HP AlertMail-SEQ:
To: RECEIVER MAILBOX
84
Configuring HP Integrity Superdome 2 compute enclosures and enclosure devices