beautypg.com

Diagnostic information – HP Integrity Superdome 2 Server User Manual

Page 81

background image

Diagnostic information

Diagnostic information is gathered by polling a device microcontroller (resulting in a degraded
status if a failure has occurred), or is sent by the device microcontroller, without being polled to
report a failure.

Description

Item

Contains information on model name, part number, serial number, and other information
used to identify the device. This data is also called FRU data. Device identification data
error displays if the data is not present or not readable by the Onboard Administrator.

Device Identification Data

Possible values are OK or Error. View the syslog for errors. Possible reasons for the error
are mismatched firmware or a software or hardware failure.

Device Operational

Indicates if the device has been indicted by the Superdome 2 Analysis Engine.

Device Indictment

Table 7 Subsystems and Devices information

Description

Table

The overall status of all device bays. Possible values are Unknown, OK, Degraded, and
Failed.

Device Bay Overview

All Device Bays

The overall status of the interconnect bays. Possible values are Unknown, OK, Degraded,
and Failed.

Interconnect Bay Overview

All Interconnect Bays

The overall status of the XFM bays. Possible values are Unknown, OK, Degraded, and
Failed.

X–Flex Bay Overview
All XFM Bays

The overall status of the GPSM bays. Possible values are Unknown, OK, Degraded, and
Failed.

GPSM Bay Overview
All GPSM Bays

The overall status of the Power Subsystem of the enclosure. Possible values are Unknown,
OK, Degraded, and Failed.

Power Subsystem

System Status

The overall status of the power supplies. Possible values are Unknown, OK, Degraded,
and Failed.

Power Supply Summary

All Power Supplies

The overall thermal status of the enclosure. Possible values are Unknown, OK, Degraded,
and Failed.

Thermal Subsystem

System Status

The overall status of the fans. Possible values are Unknown, OK, Degraded, and Failed.

Fan Overview

All Fans

NOTE:

If any subsystem contains a component with a status other than OK, all components of

that subsystem with a status other than OK are displayed inline.

Enclosure settings

81