Toolkit utilities 53
Error code
Error message
Comment or clarification
2824
Invalid expand priority.
This error message appears if the expand priority value
specified in the script is not supported. This message also
appears if expansion is not possible because the Expand Priority
feature is then not supported. (Expansion might be temporarily
unavailable on a controller that normally supports expansion if,
for example, the cache battery has low charge, another
expansion or migration is already in progress, or the array has
the maximum supported number of physical drives.)
2825
Invalid array.
The array ID is invalid.
2826
Array not specified.
The script file has commands that require an array, but no array
is specified.
2827
New array ID does not match
the next available array ID.
The scripted array ID is not the next ID in sequence, based on the
IDs of the existing arrays. For example, only array A exists and
the script file specifies creation of array C (omitting array B).
2828
New array ID already exists. This error occurs in Configure mode when the array ID specified
in the script file already exists in the configuration. In Configure
mode, you can create only new arrays.
2829
Cannot create array.
The controller has no unassigned physical drives, or it already
has the maximum number of arrays or logical drives.
2830
Cannot expand array.
The controller does not support expansion, or the current
controller configuration is not expandable.
2831
Cannot change array spare. This error message appears if you try to change the number of
spares in an array when the configuration does not support the
addition or subtraction of spares.
2832
Invalid physical drive.
A specified physical drive is not a valid physical drive, or it
cannot be placed in the array.
2833
Invalid spare.
A specified spare is not a valid spare drive, or it cannot be
placed in the array as a spare.
2834
Invalid logical drive.
—
2835
Logical drive not specified.
The script file has commands that require a logical drive, but no
logical drive is specified.
2836
New logical drive ID does not
match the next available
logical drive ID.
The script file specifies a logical drive ID that is not the first
unused ID in the sequence. For example, this message appears if
the controller has only logical drive 1 and the script file specifies
creation of logical drive 3 (omitting logical drive 2). A common
cause of this error is that the input file specifies nonsequential
logical drive numbers. In this case, change the logical drive
numbers in the input file so that they are sequential.
2837
New logical drive ID already
exists.
This error occurs in Configure mode when the logical drive ID
specified in the script file already exists in the configuration. In
Configure mode, you can create only new logical drives.
2838
Cannot create logical drive. The array has no free space, or the maximum number of logical
drives has already been reached.
2839
Cannot migrate logical drive
RAID.
The controller does not support RAID migration, or migration is
not possible with the current controller configuration.
2840
Cannot migrate logical drive
stripe size.
The controller does not support stripe size migration, or
migration is not possible with the current controller
configuration.