beautypg.com

Drivetype, Onlinespare, Logical drive category – HP Linux Server Management Software User Manual

Page 48: Arrayaccelerator

background image

Toolkit utilities 48

DriveType

The value that you enter for this option specifies the type of drive (SAS, SATA, or parallel SCSI) that ACU must

use to build the array.

OnlineSpare

The value for this option determines whether the array specified previously in the script will be configured
with spare drives.

Method mode

Possible values

Default value

Custom

To specify exactly which drives to use as spares,
use the applicable convention (port:ID, box:bay,
or port:box:bay).

To specify only the number of spares (not the
exact IDs), enter that number as the value for this
option. ACU automatically selects only those

drives that are suitable for the array.
To specify that the array should not have spares,
enter None.

In Configure action mode: None
In Reconfigure action mode, ACU
ignores any value entered for this

option and keeps any spares that are
already present in the configuration

Auto

Yes (indicating one spare)

No

In Configure action mode: Yes

(indicating one spare)
In Reconfigure action mode, ACU
ignores any value entered for this

option and keeps any spares that are
already present in the configuration

Logical Drive category

The Logical Drive category has the following options:

ArrayAccelerator (on page

48

)

LogicalDrive (on page

49

)

LogicalDriveSSPState (on page

49

)

ParityGroups (on page

49

)

PreferredPath (on page

49

)

RAID (on page

49

)

Sectors (on page

50

)

Size (on page

50

)

SSPAdaptersWithAccess (on page

50

)

StripeSize (on page

50

)

ArrayAccelerator

This option specifies whether the array accelerator is enabled or disabled for the specified logical drive. The
default value is Enabled.