Troubleshooting 64

Troubleshooting

Troubleshooting table

Issue

Troubleshooting

Data loss in Toolkit

Improper use of the Toolkit utilities and modification of the CONREP data files can

result in loss of critical data. Because of the potential data-loss risk, only experienced
individuals should use the Toolkit utilities. Before using the Toolkit, all necessary
precautions must be taken to ensure that mission-critical systems remain online if a

failure occurs.

Configuring options

using Toolkit utilities

Not all options can be configured using Toolkit utilities. Some options must be
configured manually or with other configuration utilities, which are available online,

before they can be used with the Toolkit. For more information on configuration, see the
option documentation.

Input files for
HPONCFG

Because the -w argument does not capture certain types of information, such as the
administrator password, data files created with HPONCFG using the -w argument
cannot then be used as input files for HPONCFG, unless they are modified first.

Sample script files

The script files and script segments in this guide are provided only as examples. You
must modify the scripts for your environment. When creating or modifying your own
scripts, the pause command is a valuable tool to help you determine that each step of

the script is functioning as desired.

HP ProLiant drivers

HP ProLiant drivers must be added during Windows® PE customization to ensure the
Toolkit utilities function properly. See the readme.txt file provided.

WMI support

HP software requires that WMI support be enabled to function in Windows® PE
properly.

Non-functioning IFHW IFHW is case-sensitive. Incorrect case, misspellings, and incorrect spacing cause the

query to fail.

CONREP version

compatibility

The file format for the DOS version of CONREP and the current version of CONREP are

not compatible.

HPACUSCRIPTING

support

HPACUSCRIPTING supports only HP Smart Array controllers. Review the

HPACUSCRIPTING documentation for the latest information.

Booting from a USB

drive key

Booting from a USB drive key is supported only on certain ProLiant servers. For more
information, see the HP Insight Foundation suite for ProLiant website

(

http://www.hp.com/go/foundation

).

Customizing the

DEPLOYSERVER.CMD
script

The IFHW and HWQUERY utilities can be used to customize the DEPLOYSERVER.CMD
script for your environment. For more information about these utilities, see the Toolkit

utilities (on page

25

) section.

SETBOOTORDER

changes

Any changes you make to the SETBOOTORDER will take effect at the next reboot.