beautypg.com

Logicaldrive, Logicaldrivesspstate, Paritygroups – HP Linux Server Management Software User Manual

Page 49: Preferredpath, Raid

background image

Toolkit utilities 49

LogicalDrive

The value that you enter for this option specifies the ID number of the logical drive that is to be created or

modified. The first logical drive on an array must have an ID of 1 (not 0), and logical drive numbering must
be contiguous.

In Configure action mode, ACU accepts only the ID number of the next possible logical drive.

In Reconfigure action mode, ACU also accepts the ID number of any existing logical drive.

LogicalDriveSSPState

This option is valid only for controllers that enable SSP on a logical drive basis. Other controllers that support

SSP use the SSPState option ("

SSPState

" on page

46

).

The following defaults apply:

For new logical drives, the default value is Disabled.

For existing logical drives, the default value is the current logical drive setting.

ParityGroups

When you create a RAID 50 or RAID 60 configuration, you must also set the number of parity groups.
You can use any integer value greater than 1 for this setting, with the restriction that the total number of
physical drives in the array must be exactly divisible by the number of parity groups.
The maximum number of parity groups possible for a particular number of physical drives is the total number

of drives divided by the minimum number of drives necessary for that RAID level (three for RAID 50, four for
RAID 60).

PreferredPath

If you select the Manual setting for PreferredPathMode (on page

45

), use the PreferredPath

command to specify the path for I/O to the logical drive on a redundant controller in active/active mode.
The default setting for this option is 1. With this setting, the controller in chassis slot 1 is the preferred

controller for I/O to the logical drive. If you select 2, the controller in chassis slot 2 becomes the preferred
controller for the logical drive.
To determine the chassis slot numbers, use the show command on a controller that supports redundant

controllers.

RAID

The value that you enter for this option specifies the RAID level of the logical drive.

When the Action mode is Configure, and the Method mode is Auto, ACU automatically selects the

highest RAID level that the controller and drive configuration can support except RAID 50 or RAID 60.
To specify RAID 50 or 60 for a controller that supports either of these RAID levels, use the Custom

setting. In this case, you must also specify the number of parity groups ("

ParityGroups

" on page

49

).

When the Action mode is Reconfigure, the default value is the existing RAID level for that logical drive.

If you specify a different RAID setting, then ACU either ignores the new setting (when Method mode is
Auto), or attempts to migrate the logical drive to the specified RAID level (when Method mode is

Custom).

This manual is related to the following products: