Pair operation window – HP StorageWorks XP Remote Web Console Software User Manual
Page 121

Table 27 Journal Operation Window Details (continued)
Description
Item
•
Assign R-Cmd.Dev: Assign a remote command device
to a mirror.
•
Release R-Cmd.Dev: Release an assigned remote
command device.
•
Blank: Nothing will occur when you click Apply.
The number to the left of the slash (/) indicates the number
of items appearing in the Preview list. The number to the
Preview
right of the slash indicates the maximum number of items
that can appear in the Preview list. For example, if Preview
010/4096 appears, you can add another 4,086 items to
the Preview list.
Applies settings in the Preview list to the storage systems
Apply
Cancels settings in the Preview list
Cancel
Information on the Journal Operation window will be updated when you do one of the following:
•
Click Apply.
•
Select another tab, and then click the Journal Operation tab again.
•
Select File, Refresh on the menu bar of the Remote Web Console main window.
•
Select Modify mode when you are in View mode.
Pair Operation Window
Use the Pair Operation window to manipulate pairs of primary and secondary data volumes.
To open the Pair Operation window, do one of the following:
•
If XP Continuous Access Journal has not been started:
Select Go, XP Continuous Access Journal, and then Pair Operation on the menu bar of the
Remote Web Console main window.
XP Continuous Access Journal starts and the Pair Operation window opens.
•
If XP Continuous Access Journal has already been started:
Select the Pair Operation tab. The Pair Operation window opens.
Pair Operation Window
121