Running an Internal Test

L

ib

r

ar
y

O
p

er
at
io

n

Running an Internal Test

1 2

ADMIN*

PSWD 000 000 000

TEST*

WARNING

Class II laser light is generated in this library. If operating the library
with access panels removed or with less than three tape magazines
installed with the interlocks disabled and the front door open, do not
stare into the light from the bar code reader.

Laser light warning labels are located adjacent to the side access
panels and the top access panel.

CAUTION

Some diagnostic tests, such as Exchange Demo, may place tape cartridges in
unexpected locations, which can cause problems with the software
application being used.

NOTE

Some diagnostic tests can only be run through the SCSI interface. Refer to
Digital Linear Tape Drive and Library SCSI-2 Command Reference

(HP

part number 5960-7674) for information about these tests.

To run self-diagnostic tests:

1. Verify that the drive status displays (if not, press

CANCEL

until it does).

2. Press

NEXT

until

ADMIN*

displays, then press

ENTER

.

3. Enter the three-part numerical password (see “Entering the

Administration Menu Password” on page 4-7).

4.

INFO*

displays. Press

NEXT

or

PREV

until

TEST*

displays, then press

ENTER

.

5. Press

NEXT

until test to run displays, then press

ENTER

.

6.

NUM LOOPS #

, where “#” is flashing and represents the number of test

cycles the test will go through.

7. Press

NEXT

to specify the number of cycles, then press

ENTER

to start the

test.

NOTE

Press

CANCEL

at any time to abort a test.

TEST CANCEL - WAIT