1-8
Product Description
Specifications
Recording format
128 track serial serpentine variable
block (64 pairs)
256-tpi track density
208 track serpentine (52 quads)
416-tpi track density
Data compress
algorithm
DLZ
DLZ
Reliability
Soft read error rate
1 in 10
7
bytes minimum
(read as one error maximum
allowable in 10
7
of data read
minimum)
1 in 10
7
bytes minimum
(read as one error maximum
allowable in 10
7
of data read
minimum)
Soft write error rate
1 x 10
6
bytes minimum
1 x 10
6
bytes minimum
Hard read error rate
1 x 10
17
bytes minimum
1 x 10
17
bytes minimum
Hard write
error rate
Not allowed
Not allowed
Undetected
error rate
1 x 10
30
bits read
1 x 10
27
bits read
MTBF
80,000 hours
200,000 hours
Head life
10,000 hours
30,000 hours
Power Specifications
Total Power
consumption
22 W (average)
33 W (maximum)
37 W (average)
47 W (maximum)
5 volt supply
5.0 V +/- 5% (maximum)
@2.5 A (average),
3.0 A (maximum)
5.0 V +/- 5% (maximum)
@3.6 A (average),
3.8 A (maximum)
12 volt supply
12.0 V +/- 5%
@ 0.8 A (average),
1.5 A (maximum)
12.0 V +/- 5%
@ 1.6 A (average),
2.6 A (maximum)
Table 1-5
DLT Drive Specifications (Continued)
Characteristic
DLT4000
DLT7000
- StorageWorks MSL6000 Tape Library (61 pages)
- Лент-е накопители HP StoreEver DAT (64 pages)
- Лент-е накопители HP StoreEver DAT (50 pages)
- Linear Tape File System Software (28 pages)
- Linear Tape File System Software (25 pages)
- StoreEver Ultrium Tape Drives (78 pages)
- StoreEver Ultrium Tape Drives (76 pages)
- Linear Tape File System Software (20 pages)
- StoreEver Ultrium Tape Drives (61 pages)
- StoreEver TapeAssure Software (40 pages)
- StoreEver Ultrium Tape Drives (75 pages)
- StoreEver Ultrium Tape Drives (60 pages)
- 2600fx Optical Disk Drive (65 pages)
- Ленточный автозагрузчик HP StorageWorks DAT 72x10 (58 pages)
- 2000fc Modular Smart Array (150 pages)
- StorageWorks 1000 Modular Smart Array (72 pages)
- StorageWorks 1000 Modular Smart Array (81 pages)
- StorageWorks 1500cs Modular Smart Array (48 pages)
- StorageWorks 1500cs Modular Smart Array (52 pages)
- StorageWorks 1500cs Modular Smart Array (71 pages)
- Servidor de almacenamiento HP ProLiant DL585 G2 (152 pages)
- Sistemas de almacenamiento de red HP StorageWorks X3000 (152 pages)
- Software de HP StoreVirtual VSA (85 pages)
- Software de HP StoreVirtual VSA (127 pages)
- X500 Data Vault (331 pages)
- StorageWorks 1000i Virtual Library System (122 pages)
- 200 Storage Virtualization System (176 pages)
- XP Array Manager Software (101 pages)
- StorageWorks XP Remote Web Console Software (20 pages)
- StorageWorks MSA 2.8 SAN Switch (22 pages)
- StorageWorks MSA 2.8 SAN Switch (104 pages)
- StorageWorks MSA 2.8 SAN Switch (270 pages)
- StorageWorks MSA 2.8 SAN Switch (307 pages)
- StorageWorks All-in-One SB600c Storage Blade (80 pages)
- StorageWorks All-in-One SB600c Storage Blade (78 pages)
- StorageWorks All-in-One SB600c Storage Blade (60 pages)
- StorageWorks All-in-One SB600c Storage Blade (72 pages)
- ProLiant DL585 G2 Storage-Server (150 pages)
- Data Protector Express Basic-Software (83 pages)
- Data Protector Express Basic-Software (93 pages)
- ProLiant DL185 G5 Storage Server (174 pages)
- ProLiant High Availability Storage Server (72 pages)
- 2000I G2-Modular-Smart-Array (48 pages)
- P2000 G3 MSA Array Systems (58 pages)
- StorageWorks 2000fc G2 Modular Smart Array (76 pages)