background image

4-25

Library Operation

Setting Configuration Options

L

ib

r

ar
y

O
p

er
at
io

n

The following table describes the available configurations.

Table 4-5

Configuration Options

Config Name

Description

Default

RECOVERY
ON/OFF

ON

Library attempts to recover from errors.

OFF

Library immediately stops moving if an error
condition occurs.

Default is RECOVERY ON, and recovery should remain ON
under normal conditions.

ON

RESTORE
DEFAULTS

Sets all library configurations back to their default settings.

CLEAR
ODOMETERS

Used by service personnel only.

Sets all library odometers back to zero.

STARWARS
ON/OFF

Used by service personnel only. Set to ON during normal
operation.

ON

Library runs with the vertical sensors enabled.

OFF

Library runs with the vertical sensors disabled.

ON

NEW PASSWORD

Changes the numerical password required to access

ADMIN*

options (configurations, tests, and information logs). To
change the password, see “Setting a New Administration Menu
Password” on page 4-8.

SECURE ON/OFF

Toggles between ON and OFF. If the configuration is set to ON,
tape magazines cannot be loaded or removed. If the
configuration is set to OFF, the library operates in its default
state, which allows cartridges to be loaded and removed.

OFF

POWER SECURE
ON/OFF

ON

SECURE ON/OFF configuration setting is retained
after a power outage.

OFF

Library returns to its default setting of POWER
SECURE OFF when power is returned after being shut
off.

OFF