beautypg.com

Installing a non-hot-plug expansion board – HP ProLiant DL380 G3 Server User Manual

Page 94

background image

94

HP ProLiant DL380 Generation 3 Server User Guide

Installing a Non-Hot-Plug Expansion Board

1. Power down the server ("Powering Down the Server" on page 37).

2. Extend the server from the rack, if applicable ("Extending the Server from

the Rack" on page 38).

3. Remove the access panel ("Removing the Access Panel" on page 40).

4. Remove the PCI riser cage ("Removing the PCI Riser Cage" on page 40).

CAUTION: To prevent damage to the server or expansion

boards, power down the server and remove all AC power cords before
removing or installing the PCI riser cage.

5. Remove the expansion slot cover for expansion slot 1 ("Removing

Expansion Slot Cover 1" on page 91).

6. Unlock the PCI retaining clip.

HP CONFIDENTIAL

File Name: 303130-3.doc Last Saved On: 7/7/03 1:48 PM