HP ProLiant DL380 Generation 3 Server User Guide

1. Unlock the hinge on the cable management arm and swing the arm away

from the server.

2. Identify the power supply configuration:

− If AC power supplies are installed, power down the server, disconnect

power cables from the back of the server, and continue with the next
step.

− If replacing a non-redundant DC power supply, power down the server,

disconnect the power cable from the back of the server, and then skip to
step 6.

− If adding a redundant DC power supply, continue with the next step.
− If replacing a redundant DC power supply, disconnect the power cord

from the redundant power supply and skip to step 6.

3. Determine the needed length of the DC power cord:

WARNING: To reduce the risk of electric shock or damage

to the equipment, do not connect the power cord to the power
supply until the power supply is installed.

a. Place the power supply end of the DC power cord near the power supply

bay area of the server. Do not plug the DC power cord into a power
supply.

HP CONFIDENTIAL