Configuring Online Spare Memory

To configure online spare memory:

1. Install the required DIMMs ("Memory Options" on page 69).

2. Access RBSU by pressing the F9 key during powerup when the prompt is

displayed in the lower right corner of the screen.

3. Select

System Options.

4. Select

Advanced Memory Protection.

5. Select

Online Spare with Advanced ECC Support.

6. Press

the

Enter key.

7. Press

the

Esc key to exit the current menu or press the F10 key to exit

RBSU.

For more information on online spare memory, refer to the white paper on the HP
website
(

http://www.compaq.com/support/techpubs/whitepapers/tm010301wp.html

).

Re-Entering the Server Serial Number

After you replace the system board or clear NVRAM, you must re-enter the
server serial number.

1. During the server startup sequence, press the F9 key to access RBSU.

2. Select

the System Options menu.

3. Select Serial Number. The following warning is displayed:

WARNING! WARNING! WARNING! The serial number is loaded

into the system during the manufacturing process and

should NOT be modified. This option should only be used

by qualified service personnel. This value should always

match the serial number sticker located on the chassis.

4. Press

the

Enter key to clear the warning.

5. Enter the serial number and press the Enter key.

6. Press

the

Escape key to close the menu.