Token ring diagnostics, Table 9.11 – HP Jetdirect 280m 802.11b Wireless Print Server User Manual
Page 164
ENWW
HP Jetdirect Configuration Page 23
Token Ring Diagnostics
Information in this section of the Jetdirect configuration page
(Token Ring Only) is described in
Table 9.11
Token Ring Diagnostic Information (1 of 2)
Message
Description
Status:
Identifies a status condition.
Ready: Indicates successful access to the Token Ring
network.
Error: Indicates an error condition. See the the error codes
and ring status messages for more information.
Code:
The following Open command error codes may be detected:
Function Failure: The HP Jetdirect print server is unable to
transmit to itself while wrapped through its lobe at the Token
Ring wiring concentrator. This message may also indicate
that data frames were received before physical insertion.
Signal Loss: Indicates one of the following:
●
The HP Jetdirect print server has detected a loss
of signal on the ring. Check the cable from the
HP Jetdirect print server to the network and check the
wiring concentrator.
●
A signal loss condition has been detected at the
HP Jetdirect print server receiver input during the open
process (either when wrapped or inserted onto the ring).
Timeout: The HP Jetdirect print server fails to logically insert
onto the ring before the insertion timer expires. Each phase
of the insertion process must complete before expiration of
the 18-second insertion timer.
Ring Failure: The HP Jetdirect print server times out when
attempting a ring purge after becoming the active monitor;
that is, the HP Jetdirect print server is unable to receive its
own ring purge data frames.
Ring Beaconing: The HP Jetdirect print server receives a
beacon data frame after physically inserting into the ring.
This indicates a break in the ring.
Dup Node Address: The HP Jetdirect print server found
another station on the ring that already has the address
which the HP Jetdirect print server wishes to use. Make sure
that all addresses are unique.