Environmental requirements

To ensure proper operation, the switch must not be subjected to environmental conditions

beyond those for which it was tested. The ranges specified in

Table 17

list the acceptable

environment for both operating and non-operating conditions.

Table 17 Environmental requirements

Condition

Acceptable range during operation

Acceptable range during

non-operation

Ambient

temperature

104°F/40 °C at sea level, derated 1 C

per 1000 ft above sea level

-40°C to 70°C with maximum rate of

change of 20 C /hr

Humidity

5% to 90% relative humidity,

non-condensing

50% to 80% relative humidity,

non-condensing

Altitude

0 to 10,000 ft (3 km) above sea level

0 to 40,000 ft (12 km) above sea level

Shock

40 G, 2mS duration

140 G, 2mS,

Vibration

0.5 G, 10–500 Hz

2.0 G, 5–500 Hz

Airflow

47 cubic ft/minute

None required

Supported SFPs

Do not use unsupported SFPs; they can affect switch operability. They may not fit correctly

and may void your warranty. See

Optional hardware kits

for a list of supported SFPs.

For a complete list of supported devices, refer to the latest version of the HP

StorageWorks SAN design reference guide:

http://h18000.www1.hp.com/products/

storageworks/san/documentation.html

.

Supported HBAs

For a list of HBAs that have been tested and are known to work with the SAN switches,

refer to the latest version of the HP StorageWorks SAN design reference guide:

http://h18000.www1.hp.com/products/storageworks/san/documentation.html

.

76