Environmental requirements
To ensure proper operation, the switch must not be subjected to environmental conditions
beyond those for which it was tested. The ranges specified in
list the acceptable
environment for both operating and non-operating conditions.
Table 17 Environmental requirements
Condition
Acceptable range during operation
Acceptable range during
non-operation
Ambient
temperature
104°F/40 °C at sea level, derated 1 C
per 1000 ft above sea level
-40°C to 70°C with maximum rate of
change of 20 C /hr
Humidity
5% to 90% relative humidity,
non-condensing
50% to 80% relative humidity,
non-condensing
Altitude
0 to 10,000 ft (3 km) above sea level
0 to 40,000 ft (12 km) above sea level
Shock
40 G, 2mS duration
140 G, 2mS,
Vibration
0.5 G, 10–500 Hz
2.0 G, 5–500 Hz
Airflow
47 cubic ft/minute
None required
Supported SFPs
Do not use unsupported SFPs; they can affect switch operability. They may not fit correctly
and may void your warranty. See
for a list of supported SFPs.
For a complete list of supported devices, refer to the latest version of the HP
StorageWorks SAN design reference guide:
.
Supported HBAs
For a list of HBAs that have been tested and are known to work with the SAN switches,
refer to the latest version of the HP StorageWorks SAN design reference guide:
.
76