beautypg.com

Powering on and off, Interpreting led activity – HP Brocade 4Gb SAN Switch for HP BladeSystem c-Class User Manual

Page 45

background image

CAUTION:

Diagnostic tests can temporarily lock the transmit and receive speed of the links during

diagnostic testing.

For information about specific diagnostic tests, refer to the latest version of the HP

StorageWorks Fabric OS administrator guide or type help followed by the name of

the diagnostic test.

Powering on and off

4Gb SAN Switch power is provided by the enclosure. The 4Gb SAN Switch will run

POST by default each time power to the enclosure is turned on. The POST process

can last as long as three minutes.
To remove power from the switch, remove the 4Gb SAN Switch from the enclosure

interconnect bay.

NOTE:

Each time the 4Gb SAN Switch is powered on, its settings are restored to the last

saved configuration.

Interpreting LED activity

You can monitor switch activity and status by checking 4Gb SAN Switch LEDs.
There are three possible LED states: no light, a steady light, or a flashing light. The

steady lights and flashing lights can be green or amber.
The LEDs flash any of these colors during boot, POST, or other diagnostic tests. This is

normal and does not indicate a problem unless the LEDs do not indicate a healthy state

after all boot processes and diagnostic tests are complete. A healthy state is indicated

by a steady green light. See

Table 12

for details about LED activity.

Brocade 4Gb SAN Switch for HP c-Class BladeSystem

45