beautypg.com

Disabling and enabling a switch, Disabling and enabling a port – HP Brocade 4Gb SAN Switch for HP BladeSystem c-Class User Manual

Page 36

background image

Disabling and enabling a switch

By default, the switch is enabled after power on and diagnostics and switch initialization

routines complete. You can disable and re-enable the switch as necessary.
To disable:

1.

If you have not already done so, connect to the switch and log in as admin as

described in

Connect to the Command Line Interface

.

2.

Issue the switchDisable command.
All Fibre Channel ports on the switch are taken offline. If the switch was part of a

fabric, the fabric reconfigures.
To enable:

1.

If you have not already done so, connect to the switch and log in as admin as

described in

Connect to the Command Line Interface

.

2.

Issue the switchEnable command.
All Fibre Channel ports that pass the Power-on Self Test (POST) are enabled. If the

switch has interswitch links (ISLs) to a fabric, it joins the fabric.

Disabling and enabling a port

To enable a port:

1.

Connect to the switch and log in as admin as described in

Connect to the

Command Line Interface

.

2.

Issue portenable portnumber where portnumber is the port number of the port

you want to enable.
To disable:

1.

If you have not already done so, connect to the switch and log in as admin as

described in

Connect to the Command Line Interface

.

2.

Issue portdisable portnumber where portnumber is the port number of

the port you want to disable.

36

Setup