Error Messages

HP AutoSYNC User’s Guide522580-021

D-9

Critical Event Messages

402

Cause. The monitor process has been intentionally abended to produce a saveabend
file for problem diagnosis.

Effect. The primary monitor process abends. The backup process takes over and
continues processing.

Recovery. Send the saveabend file to product support.

403

Cause. An operation was attempted, but no license for that service has been installed.

Effect. The operation is rejected.

Recovery. Obtain and install the necessary license.

411

Cause. A logic error has been detected by the product.

Effect. The process abends.

Recovery. Collect the saveabend file and report the error information to product
support.

412

Cause. An attempt to resize the extended segment failed.

Effect. The process abends.

Recovery. The error number is provided in the message. Determine the reason for the
failure and correct it.

413

Cause. An attempt to allocate memory in the extended segment failed.

Monitor intentionally abended

Invalid license

Assertion failure

Resize segment error

Memory pool allocation error