Configuring and Testing the Tape Library

L700 (CTL700) Installation and User’s Guide 527338-008

5- 15

Installing Diagnostic and Cleaning Cartridges

3. Attach a DG 000 label to all applicable diagnostic cartridges.

Diagnostic and Cleaning Cartridge Cells

This procedure applies to the Reserved Cells area (shown in

Figure 5-3

). This area is

reserved for cleaning and diagnostic cartridges for each tape drive type. The reserved
cells are located below CAP B (for tape libraries with two CAPs) or below the front
viewing window (for tape libraries with two CAPs), or below the front viewing window
(for tape libraries with only one CAP).

Reserved Cell Descriptions

In

Figure 5-3

on page 5-15, the top cell is reserved for in-transit cartridges. Do not

place any cartridges into this cell. This cell has two functions:

It allows the robot to swap tape cartridges within the tape library.

It is used as a drop-off cell in case the tape library loses power and the robot has a
cartridge in the hand.

Figure 5-3. Reserved Cells