beautypg.com

Configuration overview, Adding the control path and data path, S-series server with the ioam enclosure – HP NonStop G-Series User Manual

Page 127

background image

L700 (CTL700) Installation and User’s Guide 527338-008

B- 1

B

Configuring the CTL700 Tape Library
for the NonStop S-Series Server
With the IOAM Enclosure

The section covers:

Configuration Overview

You can attach the tape library (control path and data path) to a NonStop S-series
server via an IOAM enclosure. The tape library attaches to the FCSA (Fibre Channel
ServerNet adapter) in the IOAM enclosure. The ServerNet switch board in the IOAM
enclosure connects to an MSEB (modular ServerNet expansion board) on a NonStop
S-series server via a fiber-optic cable.

For more information on the IOAM enclosure, see the Modular I/O Installation and
Configuration Guide
.

Adding the Control Path and Data Path

To add the control path, issue this SCF command:

SCF> ADD SCSI $device, SENDTO STORAGE, PRIMARYLOCATION
(group, module, slot), PRIMARYSAC sac-id, LUN lun-id,
PRIMARYPORT 64-bit-portname

Example:

SCF> ADD SCSI $L700, SENDTO STORAGE, PRIMARYLOCATION
(110,2,2), PRIMARYSAC 2, LUN 0, PRIMARYPORT 1234567891234567

Configuration Overview

B-1

Adding the Control Path and Data Path

B-1

Note. The control path is used to control the robot, and the data path is used to control the
tape drive.

Note. To obtain the portname numbers for your control path and data path, contact a service
representative from STK. The portname numbers used in this section are examples only.

This manual is related to the following products: