HP ProLiant ML350 Generation 4p Server User Guide

System LED and
Color

Internal Health
LED Color

Status

DIMM failure, slot X
(Amber)

Red

DIMM in slot X has failed.

DIMM in slot X is an unsupported type, and no valid
memory exists in another bank.

Amber

DIMM in slot X has reached single-bit correctable
error threshold.

DIMM in slot X is in a pre-failure condition.

DIMM in slot X is an unsupported type, but valid
memory exists in another bank.

Overtemperature
(Amber)

Red

The Health Driver has detected a cautionary
temperature level.

The server has detected a hardware critical
temperature level.

Fan (Amber)

Red

The minimum fan requirements are not being met. Fan
has failed.

Amber

A fan has failed but still meets the minimum fan
requirements (with redundant fan option only).

Hot-Plug Hard Drive IDs

SCSI models of the HP ProLiant ML350 Generation 4p server support single- or
dual-channel SCSI hard drive configurations. The single-channel configuration
(simplex) supports up to six SCSI hard drives on one channel. The dual-channel
configuration (duplex) supports two SCSI hard drives on one channel (SCSI IDs
4 and 5) and up to four SCSI hard drives on the other channel (SCSI IDs 0
through 3) with the duplex option.

The SCSI IDs for both simplex and duplex configurations are illustrated. Always
populate hard drive bays starting with the lowest SCSI ID.

This manual is related to the following products: