Safety and security benefits, Access to redundant rom settings – HP ProLiant ML350 G4 Server User Manual
Page 104
104
HP ProLiant ML350 Generation 4p Server User Guide
Safety and Security Benefits
When you flash the system ROM, ROMPaq writes over the backup ROM and
saves the current ROM as a backup, enabling you to switch easily to the alternate
ROM version if the new ROM becomes corrupted for any reason. This feature
protects the existing ROM version, even if you experience a power failure while
flashing the ROM.
Access to Redundant ROM Settings
To access the redundant ROM through RBSU:
1. Access RBSU by pressing the F9 key during powerup when the prompt is
displayed in the upper right corner of the screen.
2. Select
Advanced Options.
3. Select
Redundant ROM Selection.
4. Select the ROM version.
5. Press
the
Enter key.
6. Press
the
Esc key to exit the current menu or press the F10 key to exit
RBSU. The server restarts automatically.
To access the redundant ROM manually:
1. Power down the server ("Powering Down the Server" on page
2. Remove the access panel ("Removing Access Panel" on page
3. Set positions 1, 5, and 6 of the system maintenance switch to On.
4. Install the access panel.
5. Power up the server ("Powering Up the Server" on page
6. Wait for the server to emit two beeps.
7. Repeat steps 1 and 2.
8. Set positions 1, 5, and 6 of the system maintenance switch to Off.
9. Repeat steps 4 and 5.