System leds and internal health led combinations – HP ProLiant ML350 G4 Server User Manual
Page 19
Server
Component
Identification
19
Item LED
Description Status
16
DIMM 3 status
Off = DIMM 3 functioning (default)
Amber = DIMM 3 failed
17
DIMM 2 status
Off = DIMM 2 functioning (default)
Amber = DIMM 2 failed
18
DIMM 1 status
Off = DIMM 1 functioning (default)
Amber = DIMM 1 failed
System LEDs and Internal Health LED Combinations
When the internal health LED on the front panel illuminates either amber or red,
the server is experiencing a health event. Combinations of illuminated system
LEDs and the internal health LED indicate system status.
The front panel health LEDs indicate only the current hardware status. In some
situations, HP SIM may report server status differently than the health LEDs
because the software tracks more system attributes.
System LED and
Color
Internal Health
LED Color
Status
Processor failure,
socket X (Amber)
Red
One or more of the following conditions may exist:
•
•
•
•
•
Processor in socket X has failed.
Processor in socket X failed over to the second
processor.
Processor
X is not installed in the socket.
Processor
X is not supported.
Processor heatsink is not attached properly.
Amber
Processor in socket X is in a pre-failure condition.
Processor failure,
both sockets (Amber)
Red
Processor types are mismatched.
PPM failure (Amber)
Red
•
•
PPM has failed.
PPM is not installed, but the corresponding processor
is installed.