HP XP7 Storage User Manual
Page 73
Network Objectplaza Trace Library (HNTRLib) is already installed, the settings
will not be inherited.
To change the integrated trace file settings:
1
.
On the remote management client, double-click the following file in
Explorer:
program-installation-destination-drive:\Program Files
#
\HITACHI
\HNTRLib2\bin\hntr2utl2.exe
#
For Windows 7 (x64) , Windows Server 2008, and Windows Vista
(x64), Program Files is Program Files (x86).
The following dialog box appears.
Figure 3-2 Hitachi Network Objectplaza Trace Utility 2 Release 2.0
Dialog Box.
2
.
In Number of Files, change the number of integrated trace files.
The default is 4. You can specify a value from 1 to 16.
The value you specify here will apply to n in program-installation-
destination-drive:\Program Files\HITACHI\HNTRLib2\spool
\Hntr2n.log (n indicates a file number).
3
.
In File Size(KB), change the size of an integrated trace file.
The default is 256 (kilobytes). You can specify a value from 8 to 8192.
Specify a value greater than or equal to the setting of Buffer Size(KB).
4
.
In Buffer Size(KB), change the buffer size.
Change the buffer size for the monitoring cycle.
The default is 64 (kilobytes). You can specify a value from 8 to 2048.
Specify a value smaller than or equal to the setting of File Size(KB).
Creating an HDLM Environment
3-21
Hitachi Dynamic Link Manager (for VMware®) User Guide