Network Objectplaza Trace Library (HNTRLib) is already installed, the settings

will not be inherited.

To change the integrated trace file settings:

1

.

On the remote management client, double-click the following file in

Explorer:
program-installation-destination-drive:\Program Files

#

\HITACHI

\HNTRLib2\bin\hntr2utl2.exe

#

For Windows 7 (x64) , Windows Server 2008, and Windows Vista

(x64), Program Files is Program Files (x86).

The following dialog box appears.

Figure 3-2 Hitachi Network Objectplaza Trace Utility 2 Release 2.0

Dialog Box.

2

.

In Number of Files, change the number of integrated trace files.
The default is 4. You can specify a value from 1 to 16.
The value you specify here will apply to n in program-installation-

destination-drive:\Program Files\HITACHI\HNTRLib2\spool
\Hntr2n.log (n indicates a file number).

3

.

In File Size(KB), change the size of an integrated trace file.
The default is 256 (kilobytes). You can specify a value from 8 to 8192.

Specify a value greater than or equal to the setting of Buffer Size(KB).

4

.

In Buffer Size(KB), change the buffer size.
Change the buffer size for the monitoring cycle.
The default is 64 (kilobytes). You can specify a value from 8 to 2048.

Specify a value smaller than or equal to the setting of File Size(KB).

Creating an HDLM Environment

3-21

Hitachi Dynamic Link Manager (for VMware®) User Guide