path, HDLM assumes that an intermittent error is occurring on the path. A

path that is assumed to have an intermittent error is excluded from

automatic failback. Intermittent error monitoring is performed on each

path.
If you omit the intermittent error monitoring interval or the number of

times that the error is to occur, each setting is specified as follows:

¢

When the intermittent error monitoring interval or the number of

times that the error is to occur has not been specified before:
The intermittent error monitoring interval is set to 30 minutes, and

the number of times that the error is to occur is set to 3.

¢

When the intermittent error monitoring interval or the number of

times that the error is to occur has been specified before:
The values specified from the last time are used.

The following shows the sub-parameters that should be specified: the

error monitoring interval and the number of times that the error is to

occur:

-intvl error-monitoring-interval

Specify the monitoring interval for an intermittent error. Use a value

from 1 to 1440 minutes. The default is 30.
During intermittent error monitoring, if changes are made to the

intermittent error monitoring interval setting, the number of errors

counted on all paths until the changes are made, and the state of

exclusion from automatic failback are initialized. Monitoring then

restarts using the new settings.
The error monitoring interval specified in this parameter is stored

even if specifying -iem off disables intermittent error monitoring.

Therefore, when you re-enable intermittent error monitoring and an

error monitoring interval is not specified, intermittent error monitoring

will be started using the stored error monitoring interval.

-iemnum number-of-times-error-is-to-occur

Specify the number of times the error needs to occur for an

intermittent error to be assumed. Valid values are from 1 to 99. The

default is 3.
During intermittent error monitoring, if changes are made to the

setting for the number of times that an error is to occur, the number

of errors counted on all paths until the changes are made, and the

state of exclusion from automatic failback are initialized. Monitoring

then restarts using the new settings.
The number of times that the error is to occur is stored in the system,

even when -iem off is specified and intermittent error monitoring is

disabled. Therefore, when you re-enable intermittent error monitoring

without specifying the number of times, intermittent error monitoring

will be started using the value stored in the system.

When the set -iem on operation is executed during intermittent error

monitoring, even if you do not change the error monitoring interval or the

number of times that the error is to occur, the history of errors on all

6-18

Command Reference

Hitachi Dynamic Link Manager (for VMware®) User Guide

This manual is related to the following products: