Error code (SSB2)
A delta resync pair cannot be created due to one of the following reasons.
EB48
•
P-VOL of the Cnt Ac-J pair is different from P-VOL of the Continuous Access Synchronous pair.
•
The serial number of the primary system that is recognized by P-VOL and S-VOL is different.
The command was rejected because the secondary system did not support the delta resync
function.
EB49
A pair cannot be created because the restore journal was not registered.
EB4C
A pair cannot be created because the master journal was not registered.
EB4D
The Cnt Ac-J pair cannot be created because the timer type of master journal and restore journal
is different.
EB4F
The command was rejected because the specified S-VOL was not mounted.
EB50
The command was rejected because PIN data existed in the specified S-VOL.
EB51
The command was rejected because the specified S-VOL cannot be accessed.
EB52
The command was rejected because the specified S-VOL is blocked.
EB53
The pair cannot be created because the specified S-VOL is used as an external volume mapped
for online data migration.
EB54
The command was rejected because the specified S-VOL was online from the host.
EB57
The command was rejected because the specified journal volume or S-VOL was reserved or being
used in the storage system. Please check the status of the volume.
EB58
The command was rejected because the specified S-VOL was being migrated by Auto LUN.
Please check the status of the volume.
EB59
The command was rejected because the access attribute was set to the specified P-VOL or S-VOL
by the Data Retention.
EB5B
The command was rejected because an internal logical error occurred.
EB5C
The command was rejected because the S-VOL was already paired.
EB5E
The command was rejected because the program product of Cnt Ac-J was not installed in the
secondary system.
EB5F
The command was rejected because the P-VOL capacity is not the same as the S-VOL’s.
EB60
The command was rejected because the path between the primary and the secondary systems
was not valid.
EB61
The command was rejected because the specified P-VOL was a command device.
EB62
The command was rejected because the restore journal was already linked with another journal.
EB63
The command was rejected because the desired capacity exceeded the charging capacity of
the program product.
EB64
The command was rejected because of the abnormal end which is related to the charging capacity
of the program product.
EB65
The command was rejected and the retry processing was ordered because P-VOL SUSPENDING
was detected when the RAID Manager horctakeover (resync) command was executed.
EB66
The command was rejected because a pair is already created with the specified S-VOL by using
Compatible FlashCopy.
EB6B
The Cnt Ac-J pair create processing was doubly executed:
EB6C
•
There are no problems if the initial copy operation is restarted when the primary storage
system is powered off.
•
There are no problems if a Cnt Ac-J pair is created when the primary storage system is reset.
Troubleshooting with RAID Manager 109