Error code (SSB2)
The command was rejected because the state of master journal was other than Initial, Active, or
Stopped.
EA09
The command was rejected because the state of restore journal was invalid.
EA0A
The command was rejected because the specified S-VOL was not in SSWS status.
EA12
The command was rejected because the request was received for the S-VOL as the P-VOL.
EA13
The command was rejected because the request was received for the P-VOL as the S-VOL.
EA15
The command was rejected because the pair status was not PSUS.
EA18
The command was rejected because the state of journal was not Stopped.
EA19
The command was rejected because the journal could not execute the suspend transition, that is,
the journal was in HLDE or PSUE status.
EA1B
The command was rejected because the specified secondary journal was not in the Stopped
status.
EA1C
The command was rejected because the request was received for the S-VOL as the P-VOL.
EA1E
The command was rejected because the request was received for the P-VOL as the S-VOL.
EA20
The command was rejected because the state of journal was not Stopped.
EA22
The command was rejected because the state of S-VOL was not SSWS.
EA25
The command was rejected because the state of master journal was other than Active or Stopped.
EA29
The command was rejected because the state of restore journal was other than Active or Stopped.
EA2C
The command was rejected because the state of mater journal was other than Active.
EA33
The command was rejected because the state of restore journal was other than Active.
EA36
The command was rejected because the specified S-VOL was in the state of status transition.
EA3A
The command was rejected because the specified S-VOL was in the state of Suspending.
EA3B
The command was rejected because the desired capacity exceeded the charging capacity of
the primary system's program product.
EA40
The command was rejected because the desired capacity exceeded the charging capacity of
the secondary system's program product.
EA41
The command was rejected because the paircreate or pairresync cannot run with the journal’s
attribute or mirror status.
EA89
The command was rejected because the pair status could not be changed during the power-on
or power-off processing.
EA8A
The command was rejected because the specified volume is used in the system that consists of
multiple primary and secondary systems.
EA8B
The command was rejected because the microcode was being replaced.
EA92
The command was rejected because the volume specified for the P-VOL was initializing the pool
of Thin Provisioning.
EA95
In the configuration where three Cnt Ac-J sites are combined, a request of Cnt Ac-J pair resync
(journal resync mode) was received. However, since the specified journal did not exist, or no
pair existed in the specified journal, the command was rejected.
EA9F
The command was rejected because the desired capacity exceeded the charging capacity of
the primary system's Cnt Ac-J. Check the license capacity as well as the related program product.
EAA2
The command was rejected because the desired capacity exceeded the charging capacity of
the secondary system's Continuous Access Synchronous. Check the License capacity as well as
the related Program product.
EAA3
Troubleshooting with RAID Manager 107