Using LO100 32

The message Loading data. Please wait appears. After this message disappears, the
Temperature and Voltage sensor data appears. This data is real-time data and is updated on a

periodic basis.

Platform event filtering configuration

The PEF Configuration screen enables you to configure LO100 to take selected actions on received or
internally generated event messages. These actions include powering down the system, resetting the

system, and triggering the generation of an alert.
To enable PEF functionality you must issue the following commands in the CLP:

cd map1
oemhp i 20 10 D0 18 00 12 01 03 D2
oemhp i 20 10 D0 18 00 12 02 3F 95

To configure a PEF for a particular sensor, click the PEF button to the far right of that sensor on the
Monitoring Sensors screen. The PEF button adjacent to each sensor opens a PEF Configuration page for

that sensor.
The PEF Configuration screen contains two sections: Current PEF Entries and Add PEF Entry. The Current

PEF Entries section includes Sensor Type, Sensor Name, PEF Action, and PEF Control information. The
Add PEF Entry section enables you set an action.
Initially, there are no entries are in the Current PEF Entries section because no PEFs are defined. When

PEF entries are defined, the PEF Control field is active and enables you to set the individual entries to
enabled, disabled, or deleted.

To configure an action (PEF entry), select the desired Event Offsets, select the desired PEF Action settings,
and then click Add.