HP ProLiant SL165z G7 Server User Manual
Page 14

Configuration 14
i.
Press the down arrow (↓) key to scroll to IPMI Configuration. Press the Enter key.
ii.
Press the down arrow (↓) key to scroll to the LAN Configuration menu. Press the Enter key.
iii.
Press the down arrow (↓) key to scroll to the end, and then select DHCP IP Source.
v.
Select either of the following:
—
To set BMC NIC to Disabled, press the Enter key.
o
On DL165 G7 and And SL 165 G7 servers:
i.
Press the down arrow (↓) key to scroll to IPMI Configuration. Press the Enter key.
ii.
Press the down arrow (↓) key to scroll to the LAN Configuration menu. Press the Enter key.
vi.
Press the down arrow (↓) key to scroll to the BMC LAN Configuration menu. Press the Enter
key.
vii.
Select DHCP/static, then press the Enter key.
—
To save all changes and exit, press the F10 key. To save all changes and exit, press the F10
key.
3.
Press the F10 key to save and exit.
To restore DHCP, see "Configuring network settings using the BIOS Setup Utility."
Enabling or disabling Telnet and HTTP services from the BIOS
Setup Utility
On ML110 G6 and DL120 G6 servers:
1.
Press the down arrow (↓) key to scroll to IPMI. Press the Enter key.
2.
Press the down arrow (↓) key to scroll to the LAN Settings menu. Press the Enter key.
3.
Press the down arrow (↓) key to scroll to the Telnet Services and HTTP Services. Press the Enable or
Disable key as appropriate.
On ML150 G6 servers:
1.
Select Advanced>IPMI.
2.
Set the following:
o
BMC HTTP Service—Enabled or Disabled, as appropriate
o
BMC Telnet Service—Enabled or Disabled, as appropriate
On DL160 G6, DL160se G6, DL180 G6, and SL160z G6 servers and DL165 and SL165z G7 servers:
3.
Select either of the following:
o
If you are enabling or disabling Telnet, select Advanced>IPMI Configuration>LAN
Configuration>BMC Telnet Service.
o
If you are enabling or disabling HTTP, select Advanced>IPMI Configuration>LAN
Configuration>BMC HTTP Services.
4.
To enable or disable, press Enter.
5.
Press the F10 key to save all changes and exit.
On DL170h G6, SL170z G6, and SL2x170z G6 servers:
6.
Press the right arrow key (→) to scroll to the Advanced tab. Press the Enter key.
- ProLiant SL2x170z G6 Server ProLiant DL160 G6 Server ProLiant ML150 G6 Server ProLiant DL120 G6 Server ProLiant DL180 G6 Server ProLiant DL160se G6 Server ProLiant SL160z G6 Server Lights-Out 100 Remote Management ProLiant ML110 G6 Server ProLiant DL170h G6 Server ProLiant SL170z G6 Server ProLiant DL165 G7 Server