Using LO100 25

Time elapsed: 53 seconds.

Download Complete.

The reset command causes a target to cycle from enabled to disabled and then to enabled again.

The set command assigns a specific value to a property or group of properties. The standard syntax

for the set command is set property=new value.

The set command is used to change any changeable property. If the current directory does not

contain the property you want to change, you must specify the target of the property before entering
the property you want to change.

The start command causes the system1 target to power on.

The stop command causes the system1 target to power off.

The version command queries the version of the CLP implementation or other CLP elements. For

example:

/./map1/-> version

Version 1.00

/./map1/-> cd firmware

/./map1/firmware/-> version

Version 1.00

/./map1/firmware/-> show

/./map1/firmware

Targets

Properties

fwversion=0.59

Verbs

cd

version

exit

show

reset

load

help

/./map1/firmware/-> show fwversion

fwversion=0.59

/./map1/firmware/-> fwversion

Invalid command