HP Netserver E Server series User Manual
Page 62

Chapter 5
Error Message Reference
58
Code
Description
Recommended Action
0606h
DiagTools Error
Report error to HP Customer Care Center and get the latest version of DiagTools.
0607h
DiagTools Error
Report error to HP Customer Care Center and get the latest version of DiagTools.
0608h
FIFO register test
failed at port
XXXXh.
Possible system board failure.
0609h
FIFO trigger level
test failed at port
XXXXh.
Possible system board failure.
0610h
FIFO character
timeout indication
test failed at port
XXXXh.
Possible system board failure.
0611h
FIFO data transfer
test failed at port
XXXXh.
Possible system board failure.
0612h
Baud rate speed
test failed.
Possible system board failure. If the test is running on a 16650 UART, make sure
that the clock frequency selected in the menu matches the jumper settings on the
card.
0613h
Infrared Register
test failed at port
XXXXh.
Possible system board failure.
0614h
Infrared Interrupt
ID test failed at
port XXXXh.
Replace the system board
0615h
DiagTools Error
Report error to HP Customer Care Center and get the latest version of DiagTools.
0616h
Infrared Line Status
test failed at port
XXXXh.
Replace the system board
0617h
Infrared Data
Transfer test failed
at port XXXXh.
The test indicates that the system board is not working properly. Contact your
support provider for more details.
0701h
Parallel Port Test
Failed
Possible system board failure.
0702h
IRQ Activation test
failed at port
XXXXh.
Possible system board failure.
0704h
A register
Write/Read test
failed at port
XXXXh.
Possible system board failure.
0705h
A register FIFO test
failed at port
XXXXh.
Possible system board failure.
0706h
DiagTools Error
Report error to HP Customer Care Center and get the latest version of DiagTools.
0707h
DiagTools Error
Report error to HP Customer Care Center and get the latest version of DiagTools.
0708h
DiagTools Error
Report error to HP Customer Care Center and get the latest version of DiagTools.
0801h
DiagTools Error
Report error to HP Customer Care Center and get the latest version of DiagTools.
0802h
DiagTools Error
Report error to HP Customer Care Center and get the latest version of DiagTools.