beautypg.com

HP Netserver E Server series User Manual

Page 30

background image

Chapter 5

Error Message Reference

26

Code

Description

Recommended Action

execution error.

0007h

Verify a Segment for
Reading) instruction
execution error.

Make sure the CPU is seated properly or replace the CPU.

0008h

VERW (Verify a
Segment for Writing
instruction execution
error.)

1. Take ESD precautions and make sure the system board is seated.

2. Check the seating of the voltage regulator module (VRM) if present.

3. Be sure the processor board (if any) is seated.

4. Make sure the CPU chip is seated.

5. Make sure the memory elements (DIMMs) are properly seated.

6. Check system fans. If overheating occurs, chip may shut down.

7. If the system ran with temperature high, let it cool for 30 minutes, then restart.

8. If system repeatedly shows this error, replace the CPU chip or board, as
appropriate.

0009h

Cannot enable the
A20 line.

1. Take ESD precautions and make sure the system board is seated.

2. Check the seating of the voltage regulator module (VRM) if present.

3. Be sure the processor board (if any) is seated.

4. Make sure the CPU chip is seated.

5. Make sure the memory elements (DIMMs) are properly seated.

6. Check system fans. If overheating occurs, chip may shut down.

7. If the system ran with temperature high, let it cool for 30 minutes, then restart.

8. If system repeatedly shows this error, replace the CPU chip or board, as
appropriate.

0010h

32-bit register read
or write error.

1. Take ESD precautions and make sure the system board is seated.

2. Check the seating of the voltage regulator module (VRM) if present.

3. Be sure the processor board (if any) is seated.

4. Make sure the CPU chip is seated.

5. Make sure the memory elements (DIMMs) are properly seated.

6. Check system fans. If overheating occurs, chip may shut down.

7. If the system ran with temperature high, let it cool for 30 minutes, then restart.

8. If system repeatedly shows this error, replace the CPU chip or board, as
appropriate.

0011h

PUSHA(D) or
POPA(D) execution
error.

1. Take ESD precautions and make sure the system board is seated.

2. Check the seating of the voltage regulator module (VRM) if present.

3. Be sure the processor board (if any) is seated.

4. Make sure the CPU chip is seated.

5. Make sure the memory elements (DIMMs) are properly seated.

6. Check system fans. If overheating occurs, chip may shut down.

7. If the system ran with temperature high, let it cool for 30 minutes, then restart.

8. If system repeatedly shows this error, replace the CPU chip or board, as
appropriate.

0012h

Cannot access data
through the FS or

1. Take ESD precautions and make sure the system board is seated.

2. Check the seating of the voltage regulator module (VRM) if present.

This manual is related to the following products: