Error Message Reference

45

Code

Description

Recommended Action

technical reference label or card.

5. Examine the support ticket and check for failures.

6. Bring the system down to its minimum memory configuration and rerun the
test.

7. Build up the system by halves until the failure is located.

0135h

ECC Correctable
Error in DIMM
socket YYYY.

1. Visually inspect the memory board to ensure proper seating.

2. Check to see all DIMMs are the correct HP part number.

3. Visually inspect DIMM units to ensure they are properly seated.

4. Check the positions of DIMMs to see that positioning matches that on the
technical reference label or card.

5. Examine the support ticket and check for failures.

6. Bring the system down to its minimum memory configuration and rerun the
test.

7. Build up the system by halves until the failure is located.

0136h

ECC Uncorrectable
Error in
SIMM/DIMM socket
XXXX/YYYY.

1. Visually inspect the memory board to ensure proper seating.

2. Check to see all DIMMs are the correct HP part number.

3. Visually inspect DIMM units to ensure they are properly seated.

4. Check the positions of DIMMs to see that positioning matches that on the
technical reference label or card.

5. Examine the support ticket and check for failures.

6. Bring the system down to its minimum memory configuration and rerun the
test.

7. Build up the system by halves until the failure is located.

0137h

Error occured on
bank XXXX
interleave YYYY.

1. Visually inspect the memory board to ensure proper seating.

2. Check to see all DIMMs are the correct HP part number.

3. Visually inspect DIMM units to ensure they are properly seated.

4. Check the positions of DIMMs to see that positioning matches that on the
technical reference label or card.

5. Examine the support ticket and check for failures.

6. Bring the system down to its minimum memory configuration and rerun the
test.

7. Build up the system by halves until the failure is located.

0140h

Failure at address
XXXXXXXXh--bit
position bbh.

1. Visually inspect the memory board to ensure proper seating.

2. Check to see all DIMMs are the correct HP part number.

3. Visually inspect DIMM units to ensure they are properly seated.

4. Check the positions of DIMMs to see that positioning matches that on the
technical reference label or card.

5. Examine the support ticket and check for failures.

6. Bring the system down to its minimum memory configuration and rerun the
test.

7. Build up the system by halves until the failure is located.

0150h

Failure at
XXXXXXXXh bit
position bbh..

1. Visually inspect the memory board to ensure proper seating.

2. Check to see all DIMMs are the correct HP part number.

3. Visually inspect DIMM units to ensure they are properly seated.

4. Check the positions of DIMMs to see that positioning matches that on the