beautypg.com

HP Netserver E Server series User Manual

Page 57

background image

Chapter 5

Error Message Reference

53

Code

Description

Recommended Action

4. Check for proper termination, using technical reference card or label.

5. Check system fans

6. Check firmware version of drive and update if necessary.

7. Replace the drive

8. Change the card or board that has the drive’s controller.

0502h

SCSI device read
error.

1. Check cables and connections: a) to SCSI components, b) to power source, c)
between cards and backplane.

2. Inspect SCSI pins to ensure none are bent.

3. Check seating of board or SCSI card.

4. Check for proper termination, using technical reference card or label.

5. Check system fans

6. Check firmware version of drive and update if necessary.

7. Replace the drive

8. Change the card or board that has the drive’s controller.

0503h

SCSI disk read timed
out.

1. Check cables and connections: a) to SCSI components, b) to power source, c)
between cards and backplane.

2. Inspect SCSI pins to ensure none are bent.

3. Check seating of board or SCSI card.

4. Check for proper termination, using technical reference card or label.

5. Check system fans

6. Check firmware version of drive and update if necessary.

7. Replace the drive

8. Change the card or board that has the drive’s controller.

0504h

DiagTools Error

Download a new version of DiagTools from the HP web site and run it. If you
get the same error, call the HP Customer Care Center.

0505h

DiagTools Error

Download a new version of DiagTools from the HP web site and run it. If you
get the same error, call the HP Customer Care Center.

0506h

DiagTools Error

Download a new version of DiagTools from the HP web site and run it. If you
get the same error, call the HP Customer Care Center.

0507h

SCSI disk buffer
error.

1. Check cables and connections: a) to SCSI components, b) to power source, c)
between cards and backplane.

2. Inspect SCSI pins to ensure none are bent.

3. Check seating of board or SCSI card.

4. Check for proper termination, using technical reference card or label.

5. Check system fans

6. Check firmware version of drive and update if necessary.

7. Replace the drive

8. Change the card or board that has the drive’s controller.

0508h

SCSI disk random
read error.

1. Check cables and connections: a) to SCSI components, b) to power source, c)
between cards and backplane.

2. Inspect SCSI pins to ensure none are bent.

3. Check seating of board or SCSI card.

This manual is related to the following products: