beautypg.com

HP Netserver E Server series User Manual

Page 36

background image

Chapter 5

Error Message Reference

32

Code

Description

Recommended Action

8. If system repeatedly shows this error, replace the CPU chip or board, as
appropriate.

0050h

The Timer Periodic
Interrupt is not being
generated.

1. Take ESD precautions and make sure the system board is seated.

2. Check the seating of the voltage regulator module (VRM) if present.

3. Be sure the processor board (if any) is seated.

4. Make sure the CPU chip is seated.

5. Make sure the memory elements (DIMMs) are properly seated.

6. Check system fans. If overheating occurs, chip may shut down.

7. If the system ran with temperature high, let it cool for 30 minutes, then restart.

8. If system repeatedly shows this error, replace the CPU chip or board, as
appropriate.

0051h

The Timer is
counting at a slower
rate.

1. Take ESD precautions and make sure the system board is seated.

2. Check the seating of the voltage regulator module (VRM) if present.

3. Be sure the processor board (if any) is seated.

4. Make sure the CPU chip is seated.

5. Make sure the memory elements (DIMMs) are properly seated.

6. Check system fans. If overheating occurs, chip may shut down.

7. If the system ran with temperature high, let it cool for 30 minutes, then restart.

8. If system repeatedly shows this error, replace the CPU chip or board, as
appropriate.

0052h

The Timer is
counting at a faster
rate.

1. Take ESD precautions and make sure the system board is seated.

2. Check the seating of the voltage regulator module (VRM) if present.

3. Be sure the processor board (if any) is seated.

4. Make sure the CPU chip is seated.

5. Make sure the memory elements (DIMMs) are properly seated.

6. Check system fans. If overheating occurs, chip may shut down.

7. If the system ran with temperature high, let it cool for 30 minutes, then restart.

8. If system repeatedly shows this error, replace the CPU chip or board, as
appropriate.

0060h

The Real Time
Clock Periodic
Interrupt is not being
generated.

1. Take ESD precautions and make sure the system board is seated.

2. Check the seating of the voltage regulator module (VRM) if present.

3. Be sure the processor board (if any) is seated.

4. Make sure the CPU chip is seated.

5. Make sure the memory elements (DIMMs) are properly seated.

6. Check system fans. If overheating occurs, chip may shut down.

7. If the system ran with temperature high, let it cool for 30 minutes, then restart.

8. If system repeatedly shows this error, replace the CPU chip or board, as
appropriate.

0061h

The Real Time
Clock is running at a
slower rate.

1. Take ESD precautions and make sure the system board is seated.

2. Check the seating of the voltage regulator module (VRM) if present.

3. Be sure the processor board (if any) is seated.

4. Make sure the CPU chip is seated.

5. Make sure the memory elements (DIMMs) are properly seated.

This manual is related to the following products: