Chapter 5

Error Message Reference

37

Code

Description

Recommended Action

twice.

0097h

DiagTools Error

Download a new version of DiagTools from the HP web site and run it. If you get

the same error, call the HP Customer Care Center.

0098h

DiagTools Error

Download a new version of DiagTools from the HP web site and run it. If you get

the same error, call the HP Customer Care Center.

0099h

DiagTools Error

Download a new version of DiagTools from the HP web site and run it. If you get

the same error, call the HP Customer Care Center.

009Ah

PnP function 40
failed.

Replace System BIOS.

009Bh

Invalid number of
PnP cards.

009Ch

One or more
unknown PnP cards.

Check all PnP devices.

009Dh

No PCI bus system
device Node.

1. If necessary, update the BIOS.

2. Clear the CMOS and rerun configuration. See directions on the technical
reference label or card.

3. Make sure the system board is seated.

4. Check the seating of the voltage regulator module (VRM) if present.

5. Be sure the processor board (if any) is seated.

6. Make sure the CPU chip is seated. (Take ESD precautions.)

7. Make sure the memory elements (DIMMs) are properly seated.

8. Check system fans. If overheating occurs, chip may shut down.

9. If the system ran with temperature high, let it cool for 30 minutes, then restart.

10. If system repeatedly shows this error, replace the element with the CMOS.

009Eh

Too many PCI
busses.

1. Run the BIOS Setup program and reconfigure all settings.

2. If necessary, update the BIOS.

3. Clear the CMOS and rerun configuration. See directions on the technical
reference label or card.

4. Make sure the system board is seated.

5. Check the seating of the voltage regulator module (VRM) if present.

6. Be sure the processor board (if any) is seated.

7. Make sure the CPU chip is seated. (Take ESD precautions.)

8. Make sure the memory elements (DIMMs) are properly seated.

9. Check system fans. If overheating occurs, chip may shut down.

10. If the system ran with temperature high, let it cool for 30 minutes, then
restart.

11. If system repeatedly shows this error, replace the element with the CMOS.

009Fh

DiagTools Error

Download a new version of DiagTools from the HP web site and run it. If you get

the same error, call the HP Customer Care Center.

00A0h

PnP function 41
failed.

1. Run the BIOS Setup program and reconfigure all settings.