Error Message Reference

30

Code

Description

Recommended Action

3. Be sure the processor board (if any) is seated.

4. Make sure the CPU chip is seated.

5. Make sure the memory elements (DIMMs) are properly seated.

6. Check system fans. If overheating occurs, chip may shut down.

7. If the system ran with temperature high, let it cool for 30 minutes, then restart.

8. If system repeatedly shows this error, replace the CPU chip or board, as
appropriate.

002Bh

Integer load or store
error.

1. Take ESD precautions and make sure the system board is seated.

2. Check the seating of the voltage regulator module (VRM) if present.

3. Be sure the processor board (if any) is seated.

4. Make sure the CPU chip is seated.

5. Make sure the memory elements (DIMMs) are properly seated.

6. Check system fans. If overheating occurs, chip may shut down.

7. If the system ran with temperature high, let it cool for 30 minutes, then restart.

8. If system repeatedly shows this error, replace the CPU chip or board, as
appropriate.

002Ch

NDP Tag word read
or write error.

1. Take ESD precautions and make sure the system board is seated.

2. Check the seating of the voltage regulator module (VRM) if present.

3. Be sure the processor board (if any) is seated.

4. Make sure the CPU chip is seated.

5. Make sure the memory elements (DIMMs) are properly seated.

6. Check system fans. If overheating occurs, chip may shut down.

7. If the system ran with temperature high, let it cool for 30 minutes, then restart.

8. If system repeatedly shows this error, replace the CPU chip or board, as
appropriate.

002Dh

NDP stack pop
error.

1. Take ESD precautions and make sure the system board is seated.

2. Check the seating of the voltage regulator module (VRM) if present.

3. Be sure the processor board (if any) is seated.

4. Make sure the CPU chip is seated.

5. Make sure the memory elements (DIMMs) are properly seated.

6. Check system fans. If overheating occurs, chip may shut down.

7. If the system ran with temperature high, let it cool for 30 minutes, then restart.

8. If system repeatedly shows this error, replace the CPU chip or board, as
appropriate.

002Eh -
002Fh

NDP Tag word read
or write error.

1. Take ESD precautions and make sure the system board is seated.

2. Check the seating of the voltage regulator module (VRM) if present.

3. Be sure the processor board (if any) is seated.

4. Make sure the CPU chip is seated.

5. Make sure the memory elements (DIMMs) are properly seated.

6. Check system fans. If overheating occurs, chip may shut down.

7. If the system ran with temperature high, let it cool for 30 minutes, then restart.

8. If system repeatedly shows this error, replace the CPU chip or board, as
appropriate.