HP Integrity NonStop J-Series User Manual
Page 41
Guardian Performance Analyzer (GPA) User Guide
– (544541-006) Page 41 of 131
7> PARAM classname section-type
classname specifies the process class the optional report is run for. The classnames
are:
SYSTEM
SUBSYSTEM
PATHWAY
SERVER
TRANSIENT
OTHER
You can select more than one section for the optional report by setting one PARAM for
each class.
Section-type specifies the type of output GPA should produce. The options are:
SUMMARY
DETAIL
An optional section is run for each of the PARAMs declared. Setting a PARAM to any
other type than SUMMARY or DETAIL results in the section for that classname
not being produced. When you select DETAIL, the summary section is included.
For example, to run a detail section for the SYSTEM class and a summary for each
of the others, set the following six PARAMS:
8> PARAM SYSTEM DETAIL
9> PARAM SUBSYSTEM SUMMARY
10> PARAM PATHWAY SUMMARY
11> PARAM SERVER SUMMARY
12> PARAM TRANSIENT SUMMARY
13> PARAM OTHER SUMMARY
The default section-type is DETAIL. To refrain from printing the optional report,
specify:
14> PARAM classname NOPRINT
To suppress printing of the textual report only, enter:
15> PARAM TEXT NOPRINT
3. Run GPA to perform the analysis. Set the volume and subvolume to the location of
your measurement data and enter:
16> RUN $SYSTEM.ZGPA.OBEYTUNE
This assumes GPA has been installed to $SYSTEM.ZGPA. If this is not the case,
substitute the correct $volume.subvolume in the above command line. GPA
processes the data collected by Measure and generates the reports as well as the