background image

Command line 47

Item

Description

assigned to a device bay using the "assign" subcommand.

Syntax

add profile [-NoDefaultEnetConn] [-

NoDefaultFcConn] [-NoDefaultFcoeConn] [SNType=

Default|User-Defined>] [SerialNumber=]

[UUID=]

Parameter

ProfileName

The unique name of the new server profile to create

Options

NoDefaultEnetConn

Do not add default Ethernet Network connections when creating the server
profile.

NoDefaultFcConn

Do not add default FC SAN connections when creating the server profile.

NoDefaultFcoeConn

Do not add default FCoE SAN connections when creating the server profile.

Properties

SNType (Optional)

The source of the serial number assignment to be used during the profile

creation. If not specified, the serial number is assigned according to the Virtual
connect default domain settings. Valid values include "Factory-Default" and

"User-Defined".

SerialNumber

(required if the

SNType is User-

Defined)

A custom user-defined serial number associated with the server profile. When

the profile is assigned to a device bay that contains a server, the server inherits
the virtual serial number. The user-defined serial number must start with the
pattern VCX01.

UUID (Optional)

A unique 128-bit identifier for the virtual server ID. The format is xxxxxxxx-xxxx-
xxxx-xxxx-xxxxxxxxxxxx, where x is any alpha-numeric character. If no UUID is

specified, then one is auto-generated. The UUID can be specified only if the
SNType is User-Defined.

Examples

->add profile MyNewProfile
Creates a new profile and adds it to the domain, using default connections and
Virtual Connect default serial numbers

->add profile MyNewProfile2 -NoDefaultEnetConn
Creates a new profile without adding default Ethernet connections

->add profile MyNewProfile2 -NoDefaultFcConn
Creates a new profile without adding default FC connections

->add profile MyNewProfile2 -NoDefaultFcoeConn
Creates a new profile without adding default FCoE connections

->add profile MyNewProfile2 -NoDefaultEnetConn

-NoDefaultFcConn
Creates a new profile without adding default Ethernet and FC connections

->add profile MyNewProfile2 -NoDefaultEnetConn

-NoDefaultFcConn -NoDefaultFcoeConn
Creates a new profile without adding default Ethernet, FC, and FCoE
connections

->add profile MyNewProfile SNType=User-Defined

SerialNumber=VCX0113121
Creates a new profile and specifies a custom virtual serial number

->add profile MyNewProfile SNType=Factory-Default
Creates a new profile and uses the factory assigned serial number